How to Calibrate a Thermocouple Transmitter - Hallo sahabat APLIKASI ELECTRONIC, Pada Artikel yang anda baca kali ini dengan judul How to Calibrate a Thermocouple Transmitter, kami telah mempersiapkan artikel ini dengan baik untuk anda baca dan ambil informasi didalamnya. mudah-mudahan isi postingan Artikel Calibration, Artikel Thermocouples, yang kami tulis ini dapat anda pahami. baiklah, selamat membaca.



Judul : How to Calibrate a Thermocouple Transmitter
link : How to Calibrate a Thermocouple Transmitter

Baca juga


How to Calibrate a Thermocouple Transmitter

To calibrate a thermocouple transmitter will require a thermocouple simulator with an accuracy of at least four times greater than the thermocouple sensor we desire to calibrate. 

Equipment and Materials Required
The following equipment/materials are required to successfully calibrate a thermocouple transmitter:
  1. Thermocouple Simulator (of at least four times the accuracy of sensor)
  2. Two Digital Voltmeters (Five-digit readout) with accuracy of at least ±0.01% with resolution 1mV
  3. 24 VDC Power Supply of at least 35 – 40mA current output
  4. Thermocouple wire of the same type of wire the thermocouple transmitter is constructed of.

Equipment Setup
Below is the equipment set up for the calibration


Calibration Procedure
  1. Remove the thermocouple transmitter terminal housing cover
  2. If the transmitter is already connected, remove all the thermocouple lead connections.
  3. Determine the base and full scale temperatures. Read: How to convert thermocouple millivolt to temperature.
  4. Turn power supply on.
  5. Consult the thermocouple simulator manual for instructions on setting the thermocouple type and engineering units.
  6. Set the simulator to the base (zero) temperature and adjust the zero pot until the output is 4mA or 40mV at the test terminals
  7. Set the simulator to the full scale temperature and adjust the span pot until the output is 20mA
  8. Repeat steps (1-7) above until both the 4 and 20mA readings are obtained without re-adjusting the span and zero pots.