Process Performance of Correctly Sized, Undersized and Oversized Control Valves - Hallo sahabat APLIKASI ELECTRONIC, Pada Artikel yang anda baca kali ini dengan judul Process Performance of Correctly Sized, Undersized and Oversized Control Valves, kami telah mempersiapkan artikel ini dengan baik untuk anda baca dan ambil informasi didalamnya. mudah-mudahan isi postingan Artikel Control Valves, yang kami tulis ini dapat anda pahami. baiklah, selamat membaca.



Judul : Process Performance of Correctly Sized, Undersized and Oversized Control Valves
link : Process Performance of Correctly Sized, Undersized and Oversized Control Valves

Baca juga


Process Performance of Correctly Sized, Undersized and Oversized Control Valves

In the process of sizing and selecting control valves, there is one of three possible outcomes:
1. The valve is correctly sized or 
2. The valve is oversized or
3. The valve is undersized

Characteristics of Correctly Sized, Under-sized and Over-sized Control Valves

A Correctly Sized Control Valve (The right valve Cv)
A correctly sized valve has the required capacity to deliver the right flow rate at minimum, normal and maximum flows and helps to safeguard optimal control both as far as comfort and economy are concerned.

Oversized Control Valves (Large Cv)
An oversized valve has poor controllability. An oversized control valve implies that all normal operations will be confined to small openings of the valve with great risk of variable sensitivity and aggravation of any uneven movement of the valve. Poor accuracy and unstable control often result.
The smallest change in stroke in an oversized valve will result in large flow variations. As the valve opens or closes, large flow speeds and a powerful turbulence are created between the plug and seat. This both erodes the valve and causes noise. 

Undersized Control Valves (Small Cv)
If the control valve is undersized (Cv - too small), the required flow rate will not be achieved even when the valve is fully opened. If a higher pressure is applied to force a higher flow rate across the undersized valve; not only the pump energy will be excessive but also the valve may cavitate or develop flashing.